Illinois Administrative Code (Last Updated: March 27, 2024) |
TITLE77. PUBLIC HEALTH |
PART920. WATER WELL CONSTRUCTION CODE |
§920.TABLE A. Steel Casing and Liner Pipe Weights and Dimensions
-
SIZE
DIAMETER (in.)
THICKNESS
WEIGHT (lbs. per ft.)
in.
External
Internal
in.
Plain ends (calculated)
With threads and couplings (nominal)
1
1.315
1.049
0.133
1.68
1.70
1¼
1.660
1.380
0.140
2.27
2.30
1½
1.900
1.610
0.145
2.72
2.75
2
2.375
2.067
0.154
3.65
3.75
2½
2.875
2.469
0.203
5.79
5.90
3
3.500
3.068
0.216
7.58
7.70
3½
4.000
3.548
0.226
9.11
9.25
4
4.500
4.026
0.237
10.79
11.00
5
5.563
5.047
0.258
14.62
15.00
6
6.625
6.065
0.280
18.97
19.45
8
8.625
8.071
0.277
24.70
25.55
10
10.750
10.136
0.307
34.24
35.75
12
12.750
12.090
0.330
43.77
45.45
14
14.000
13.250
0.375
54.57
57.00
16
16.000
15.250
0.375
62.58
65.30
18
18.000
17.250
0.375
70.59
73.00
20
20.000
19.250
0.375
78.60
81.00
Pipe sizes not listed that are less than 8 inches in diameter shall be Schedule 40 pipe as a minimum.
Pipe sizes not listed that are 8 inches in diameter or greater shall be Schedule 30 pipe as a minimum.
Pipes for driven wells shall be Schedule 40 as a minimum.
(Source: Amended at 18 Ill. Reg. 17684, effective November 30, 1994)