§905.ILLUSTRATION C. List of Approved Plastic Pipe for Private Sewage  


Latest version.
  •  

     

     

     

     

    TYPES OF PIPES

    ASTM

    STANDARD

    BUILDING

    SEWER 1

    OR COMMON

    COLLECTOR

    SEWER

    LINES 1

    ALL

    SUBSURFACE

    SEEPAGE

    SYSTEMS

     

     

    5 ft. from building to septic-aeration tank to 5 ft. beyond the septic tank, aeration tank or distribution box

     

    Additional treatment facilities and sand filter distribution lines and collection lines

     

     

     

     

     

     

     

     

     

     

     

     

     

    ABS

    (DWV Schedule 40)

    F628-06

    x

    x

    x

    ABS

    (DWV Schedule 40)

    D2661-06

    x

    x

    x

    ABS

     

    D1527-99

    (2005)

    x

    x

    x

    ABS

    (Sewer Pipe)

    D2751-05

    x2

    x2

    x2

    PVC

     

    D1785-06

    x

    x

    x

    PVC

    (DWV Schedule 40)

    D2665-07

    x

    x

    x

    PVC

    (DWV Schedule 40)

    F891-04

    x

    x

    x

    PVC

    (Type PSM) (SDR 35)

    D3034-06

    x2

    x2

    x2

     

     

     

     

     

     

    PVC

    (Sewer & Drain

    PS-50)

    F891-04

    x

    x

    x

    PVC

    (Sewer & Drain

    PS-25)

    F891-04

    x

    x

     

    PVC

    (Corrugated-Smoothwall)

    F949-06

    x

    x

     

    PVC

    (Std. or Perforated)

    D2729-03

     

    x

    x

    PE

    (Smoothwall)

    R810-07

     

    x

    x

     

     

    AASHTO

    Standard

    M252-06

     

     

     

    PE

    (Corrugated-Perforated)

    F405-05

    (Heavy Duty Only)

     

     

    x

    PE

    (Corrugated-(Perforated)

    F667-06

     

     

    x

     

     

    x –

    Indicates approved use.

    l       Plastic materials shall not be co-mingled within this area except through the use of proper adapters. (See Illinois Plumbing Code.) When the building sewer is of a type of material that is different from the building drain, proper transition fittings shall be used.

    2      Pipe shall be SDR (Standard Dimension Ratio) 35 only.

    Note:

    The last 2 numbers of the ASTM Standard indicate the date of the edition.

     

    (Source:  Amended at 37 Ill. Reg. 14994, effective August 28, 2013)