§905.ILLUSTRATION C. List of Approved Plastic Pipe for Private Sewage
-
TYPES OF PIPES
ASTM
STANDARD
BUILDING
SEWER 1
OR COMMON
COLLECTOR
SEWER
LINES 1
ALL
SUBSURFACE
SEEPAGE
SYSTEMS
5 ft. from building to septic-aeration tank to 5 ft. beyond the septic tank, aeration tank or distribution box
Additional treatment facilities and sand filter distribution lines and collection lines
ABS
(DWV Schedule 40)
F628-06
x
x
x
ABS
(DWV Schedule 40)
D2661-06
x
x
x
ABS
D1527-99
(2005)
x
x
x
ABS
(Sewer Pipe)
D2751-05
x2
x2
x2
PVC
D1785-06
x
x
x
PVC
(DWV Schedule 40)
D2665-07
x
x
x
PVC
(DWV Schedule 40)
F891-04
x
x
x
PVC
(Type PSM) (SDR 35)
D3034-06
x2
x2
x2
PVC
(Sewer & Drain
PS-50)
F891-04
x
x
x
PVC
(Sewer & Drain
PS-25)
F891-04
x
x
PVC
(Corrugated-Smoothwall)
F949-06
x
x
PVC
(Std. or Perforated)
D2729-03
x
x
PE
(Smoothwall)
R810-07
x
x
AASHTO
Standard
M252-06
PE
(Corrugated-Perforated)
F405-05
(Heavy Duty Only)
x
PE
(Corrugated-(Perforated)
F667-06
x
x –
Indicates approved use.
l Plastic materials shall not be co-mingled within this area except through the use of proper adapters. (See Illinois Plumbing Code.) When the building sewer is of a type of material that is different from the building drain, proper transition fittings shall be used.
2 Pipe shall be SDR (Standard Dimension Ratio) 35 only.
Note:
The last 2 numbers of the ASTM Standard indicate the date of the edition.