Illinois Administrative Code (Last Updated: March 27, 2024) |
TITLE77. PUBLIC HEALTH |
PART890. ILLINOIS PLUMBING CODE |
SUBPARTM. INSPECTIONS, TESTS, MAINTENANCE AND ADMINISTRATION |
Section890.APPENDIX A. Plumbing Materials, Equipment, Use Restrictions and Applicable Standards |
§890.TABLE K. Size and Length of Vents
-
Size of Soil or Waste Stack
Fixture Units Connected
Diameter of Vent Required (Inches)
1¼
1½
2
2½
3
4
5
6
8
Maximum Length of Vent (Feet)
1¼
2
30
1½
8
50
150
1½
10
30
100
2
12
30
75
200
2
20
26
50
150
2½
42
30
100
300
3
10
30
100
200
600
3
30
60
200
500
3
60
50
60
400
4
100
35
100
260
1,000
4
200
30
90
250
900
4
500
20
70
180
700
5
200
35
80
350
1,000
5
500
30
70
300
900
5
1,100
20
50
200
700
6
350
25
50
200
400
1,300
6
620
15
30
125
300
1,100
6
960
24
100
250
1,000
6
1,900
20
70
200
700
8
600
50
150
500
1,300
8
1,400
40
100
400
1,200
8
2,200
30
80
350
1,100
9
3,600
25
60
250
800
10
1,000
75
125
1,000
10
2,500
50
100
500
10
3,800
30
80
350
10
5,600
25
60
250
Agency Note: Per Section 890.1580(e), no more than 20 percent of the maximum developed length may be installed in the horizontal position. Vent piping serving floor drains shall be installed in such a manner as to minimize horizontal vent distances.