§890.TABLE K. Size and Length of Vents  


Latest version.
  • Size of Soil or Waste Stack

    Fixture Units Connected

    Diameter of Vent Required (Inches)

    2

    3

    4

    5

    6

    8

    Maximum Length of Vent (Feet)

    2

    30

     

     

     

     

     

     

     

     

    8

    50

    150

     

     

     

     

     

     

     

    10

    30

    100

     

     

     

     

     

     

     

    2

    12

    30

    75

    200

     

     

     

     

     

     

    2

    20

    26

    50

    150

     

     

     

     

     

     

    42

     

    30

    100

    300

     

     

     

     

     

    3

    10

     

    30

    100

    200

    600

     

     

     

     

    3

    30

     

     

    60

    200

    500

     

     

     

     

    3

    60

     

     

    50

    60

    400

     

     

     

     

    4

    100

     

     

    35

    100

    260

    1,000

     

     

     

    4

    200

     

     

    30

    90

    250

    900

     

     

     

    4

    500

     

     

    20

    70

    180

    700

     

     

     

    5

    200

     

     

     

    35

    80

    350

    1,000

     

     

    5

    500

     

     

     

    30

    70

    300

    900

     

     

    5

    1,100

     

     

     

    20

    50

    200

    700

     

     

    6

    350

     

     

     

    25

    50

    200

    400

    1,300

     

    6

    620

     

     

     

    15

    30

    125

    300

    1,100

     

    6

    960

     

     

     

     

    24

    100

    250

    1,000

     

    6

    1,900

     

     

     

     

    20

    70

    200

    700

     

    8

    600

     

     

     

     

     

    50

    150

    500

    1,300

    8

    1,400

     

     

     

     

     

    40

    100

    400

    1,200

    8

    2,200

     

     

     

     

     

    30

    80

    350

    1,100

    9

    3,600

     

     

     

     

     

    25

    60

    250

    800

    10

    1,000

     

     

     

     

     

     

    75

    125

    1,000

    10

    2,500

     

     

     

     

     

     

    50

    100

    500

    10

    3,800

     

     

     

     

     

     

    30

    80

    350

    10

    5,600

     

     

     

     

     

     

    25

    60

    250

     

    Agency Note:  Per Section 890.1580(e), no more than 20 percent of the maximum developed length may be installed in the horizontal position. Vent piping serving floor drains shall be installed in such a manner as to minimize horizontal vent distances.