§890.TABLE H. Horizontal Fixture Branches and Stacks  


Latest version.
  •  

    Maximum Number of Drainage Fixture Units (D.F.U.)

    That May be Connected to:

     

     

     

    More than 3 Stories in Height

    Diameter of Pipe (inches)

    Any Horizontal Fixture Branch

    One Stack of 3 Stories in Height or 3 Intervals

    Total for Stack

    Total at One Story or Branch Interval

    1

    2

    2

    1

    3

    4

    8

    2

    2

    6

    10

    24

    6

    12

    20

    42

    9

    3

    201

    302

    602

    161

    4

    100

    240

    500

    90

    5

    360

    540

    1,100

    200

    6

    620

    960

    1,900

    350

    8

    1,400

    2,200

    3,600

    600

    10

    2,500

    3,800

    5,600

    1,500

    12

    3,900

    6,000

    8,400

    1,500

    15

    7,000

    1    Not over two water closets.

    2    Not over six water closets, or more than two per branch interval or per floor.