§890.TABLE E. Drainage Fixture Units (D.F.U.) Per Fixture Group  


Latest version.
  • Type of Fixture

     

    D.F.U./Fixture (Load)

    Minimum Size of Trap2 (inches)

     

     

     

    Bathroom groups:

    1 tank water closet, 1 lavatory

    with 1¼ inch trap and 1

    bathtub1 or shower stall

    7

    1 water closet with flush valve, 1

    lavatory with 1¼ inch trap and 1

    bathtub or shower1

    11

     

    Bathtub (with or without overhead shower)1

    2

    Bathtub1

    3

    2

    Bidet

    2

    Clothes washer, automatic

    3

    2

    Dental unit or cuspidor

    1

    Drinking fountain

    ½

    1

    Dishwasher2, domestic

    2

    Floor drains

    See Appendix A, Table F

    2

    Lavatories:

     

     

    Lavatory

    1

    Lavatory

    2

    Lavatory, barber, beauty parlor

    2

    Lavatory, dental

    1

    Lavatory, surgeon's

    2

    Laundry tray (1 or 2 compartments)

    2

     

    Type of Fixture

     

    D.F.U./Fixture (Load)

    Minimum Size of Trap2 (inches)

     

     

     

    Shower stall

    3

    2

    Showers (group) per head2

    3

    2


    Sinks:

     

     

    Combination sink and tray

    3

    Combination sink and tray with

    food-disposal unit

    4 Separate Traps

    Flushing rim (with valve)

    8

    3

    Kitchen sink, domestic

    2

    Kitchen sink, domestic, with food-waste

    grinder

    3 Separate Traps

    Pot, scullery, etc.2

    4

    Service (P trap)

    3

    3

    Service (P trap)

    2

    2

    Surgeon's

    3

    Wash sink2 (circular or multiple),

    each set of faucets

    2

    Urinals:

     

     

    Urinal, pedestal, siphon jet, blowout

    8

    2

    Urinal stall

    3

    2

    Urinal, wall integral trap

    3

    2

    Urinal, wall P trap, exposed

    2

    Water closets:

     

     

    Tank operated

    4

    3

    Valve-operated

    8

    3

    1A shower head over a bathtub does not increase the fixture value.

    2See Appendix A:  Table F and Section 890.1330(b) for method of determining unit values of fixtures not listed in this Table or for rating of devices with intermittent flows.

     

    (Source:  Amended at 28 Ill. Reg. 4215, effective February 18, 2004)