Illinois Administrative Code (Last Updated: March 27, 2024) |
TITLE77. PUBLIC HEALTH |
PART870. MANUFACTURED HOME INSTALLATION CODE |
§870.TABLE E. Pier Load and Minimum Pier Capacity for 12 Foot Wide Section (Pounds)
-
Roof Live Load (psf)
Mating/Perimeter Wall Opening (feet)
5
10
15
20
25
30
35
20
900
1800
2600
3500
4400
5300
6100
30
1200
2300
3500
4700
5800
7000
8200
40
1500
2900
4400
5800
7300
8800*
10200*
Soil's Load- Bearing Capacity (psf)
Footing Area (square inches)
1000
20
144
259
374
504
634
763
878
30
173
331
504
677
835
1008
1181
40
216
417
634
835
1051
1267
1469
1500
20
144
173
250
336
422
509
586
30
144
221
336
451
557
672
787
40
144
278
422
557
701
845
979
2000
20
144
144
187
252
317
382
439
30
144
166
252
338
418
504
590
40
144
209
317
418
526
634
734
3000
20
144
144
144
168
211
254
293
30
144
144
168
226
278
336
394
40
144
144
211
278
350
422
490
4000
20
144
144
144
144
191
191
220
30
144
144
144
169
209
252
295
40
144
144
158
209
263
317
367
* Individual supports shall NOT support loads greater than 8000 pounds for a single stack of 8"x8"x16" stack of blocks, 14000 pounds for a double stack.