§901.103. Sound Emitted to Class B Land  


Latest version.
  • Except as provided elsewhere in this Part, a person must not cause or allow the emission of sound from any property-line noise source located on any Class A, B or C land to any receiving Class B land that exceeds any allowable octave band sound pressure level specified in the following table, when measured at any point within the receiving Class B land. Sound pressure levels must be measured at least 25 feet from the property-line noise source.

     

    Octave Band Center Frequency (Hertz)

    Allowable Octave Band Sound Pressure Levels (dB) of Sound Emitted to any Receiving Class B Land from

     

    Class C Land

    Class B Land

    Class A Land

     

     

     

     

    31.5

    80

    79

    72

    63

    79

    78

    71

    125

    74

    72

    65

    250

    69

    64

    57

    500

    63

    58

    51

    1000

    57

    52

    45

    2000

    52

    46

    39

    4000

    48

    41

    34

    8000

    45

    39

    32

     

(Source:  Amended at 42 Ill. Reg. 20453, effective November 1, 2018)