Illinois Administrative Code (Last Updated: March 27, 2024) |
TITLE35. ENVIRONMENTAL PROTECTION |
PART219. ORGANIC MATERIAL EMISSION STANDARDS AND LIMITATIONS FOR THE METRO EAST AREA |
SUBPARTUU. RECORDKEEPING AND REPORTING |
§219.APPENDIX D. Coefficients for the Total Resource Effectiveness Index (TRE) Equation
-
The Appendix contains values for the total resource effectiveness index (TRE) equation in Subpart V.
If a flow rate falls exactly on the boundary between the indicated ranges, the operator shall use the row in which the flow rate is maximum.
COEFFICIENTS FOR TRE EQUATION
FOR CHLORINATED PROCESS VENT STREAMS WITH
NET HEATING VALUE LESS THAN
OR EQUAL TO 3.5 MJ/scm
FLOW RATE
(scm/min)
Min.
Max.
a
b
c
d
e
f
0.0
13.5
48.73
0.
0.404
-0.1632
0.
0.
13.5
700.
42.35
0.624
0.404
-0.1632
0.
0.0245
700.
1400.
84.38
0.678
0.404
-0.1632
0.
0.0346
1400.
2100.
126.41
0.712
0.404
-0.1632
0.
0.0424
2100.
2800.
168.44
0.747
0.404
-0.1632
0.
0.0490
2800.
3500.
210.47
0.758
0.404
-0.1632
0.
0.0548
COEFFICIENTS FOR TRE EQUATION
FOR CHLORINATED PROCESS VENT STREAMS WITH
NET HEATING VALUE GREATER THAN
3.5 MJ/scm
FLOW RATE
(scm/min)
Min.
Max.
a
b
c
d
e
f
0.
13.5
47.76
0.
-0.292
0.
0.
0.
13.5
700.
41.58
0.605
-0.292
0.
0.
0.0245
700.
1400.
82.84
0.658
-0.292
0.
0.
0.0346
1400.
2100.
123.10
0.691
-0.292
0.
0.
0.0424
2100.
2800.
165.36
0.715
-0.292
0.
0.
0.0490
2800.
3500.
206.62
0.734
-0.292
0.
0.
0.0548
COEFFICIENTS FOR TRE EQUATION
FOR NONCHLORINATED PROCESS VENT STREAMS WiTH
NET HEATING VALUE LESS THAN
OR EQUAL TO 0.48 MJ/scm
FLOW RATE
(scm/min)
Min.
Max.
a
b
c
d
e
f
0.
13.5
19.05
0.
0.113
-0.214
0.
0.
13.5
1350.
16.61
0.239
0.113
-0.214
0.
0.0245
1350.
2700.
32.91
0.260
0.113
-0.214
0.
0.0346
2700.
4050.
49.21
0.273
0.113
-0.214
0.
0.0424
COEFFICIENTS FOR TRE EQUATION FOR NONCHLORINATED
PROCESS VENT STREAMS WITH NET HEATING VALUE
GREATER THAN 0.48 AND LESS THAN OR
EQUAL TO 1.9 MJ/scm
FLOW RATE
(scm/min)
Min.
Max.
a
b
c
d
e
f
0.
13.5
19.74
0.
0.400
-0.202
0.
0.
13.5
1350.
18.30
0.138
0.400
-0.202
0.
0.0245
1350.
2700.
36.28
0.150
0.400
-0.202
0.
0.0346
2700.
4050.
54.26
0.158
0.400
-0.202
0.
0.0424
COEFFICIENTS FOR TRE EQUATION FOR NONCHLORINATED
PROCESS VENT STREAMS WITH NET HEATING VALUE
GREATER THAN 1.9 AND LESS THAN OR
EQUAL TO 3.6 MJ/scm
FLOW RATE
(scm/min)
Min.
Max.
a
b
c
d
e
f
.0
13.5
15.24
0.
0.033
0.
0.
0.
13.5
1190.
13.63
0.157
0.033
0.
0.
0.0245
1190.
2380.
26.95
0.171
0.033
0.
0.
0.0346
2380.
3570.
40.27
0.179
0.003
0.
0.
0.0424
COEFFICIENTS FOR THE EQUATION
FOR NONCHLORINATED PROCESS VENT STREAMS WITH
NET HEATING VALUE GREATER THAN 3.6 MG/scm
FLOW RATE
(scm/min)
Min.
Max.
a
b
c
d
e
f
0.
13.5
15.24
0.
0.
0.0090
0.
0.
13.5
1190.
13.63
0.
0.
0.0090
0.0503
0.0245
1190.
2380.
26.95
0.
0.
0.0090
0.0546
0.0346
2380.
3570.
40.27
0.
0.
0.0090
0.0573
0.0424
(Source: Amended at 17 Ill. Reg. 16918, effective September 27, 1993)